FSP Rohde Schwarz Series Spectrum Analyzer

FSP Rohde Schwarz Series Spectrum Analyzer

Welcome to a Biomedical Battery specialist of the Rohde Schwarz Battery

The FSP Series of Spectrum Analyzers from Rohde & Schwarz consists of the following models: FSP13, FSP3, FSP30, FSP38, FSP40, FSP7 with battery such as Tektronix Battery, Rohde Schwarz EB200 Battery, Rohde Schwarz FSH8 Battery, Rohde Schwarz FSH4 Battery, Rohde Schwarz HA-Z204 Battery, Rohde Schwarz Battery, Anritsu 633-75 Battery, Yokogawa AQ7270 Battery, Yokogawa AQ7275 Battery, Yokogawa Battery, NetTEST CMA4000i Battery, NetTEST CMA8800 Battery. Purchase your FSP Series model directly from our stock or request a quote to have us source it for you. We have an expansive network of new and used Rohde & Schwarz and Spectrum Analyzer suppliers to acquire what you need.

The ideal partner for both development and production, featuring good level measurement uncertainty, as well as excellent RF characteristics. The R&S FSP incorporates proven technology to enable best performance, reliability and ease of service.

The Rohde & Schwarz FSP Series of Spectrum Analyzers is capable of testing spurious emissions stipulated in the GSM specifications and has a firmware to allow adjacent-channel power (ACP) measurement to the W-CDMA/third-generation partnership project (3GPP).

This measurement is implemented in the Rohde & Schwarz FSP Series by automatic test routines which make all necessary settings, measurements and filtering. The electronic attenuator for a spectrum analyzer increases the availability for use in production and allows a number of switching operations in a wear-and-tear-free setting range of 30 dB in 5 dB steps.

Additional Features:
•Resolution bandwidth: 10 Hz to 10 MHz
•Display range: displayed average noise level to 30 dBm
•Additional filters: Channel filters from 100 Hz to 5 MHz and RRC filters, FFT filters from 1 Hz to 30 kHz, EMI bandwidths and quasi-peak detector
•Measurement functions for TOI, MC ACP(R), OBW, CCDF, APD, etc
•Measurement applications for cellular standards and general purpose, e.g. phase noise, noise figure, etc.
•DANL typ.: -155 dBm (1 Hz) w/o preamp
•Phase-noise typ: -113 dBc/Hz @ 10 kHz offset, CF 500 MHz
•Phase-noise typ: -145 dBc/Hz @ 10 MHz offset, CF 500 MHz
•TOI typ.: 10 dBm
•1-dB-compression point: 0 dBm
•0.5 dB total level uncertainty up to 3.6 GHz
•<0.2 dB linearity error down to -70 dB
•IF digitizer 12 bit 32 MHz (20.4 MHz IF)
•IQ memory 2x128 ksamples
•2.5ms sweep time in frequency domain
•1 µs sweep time in time domain
•Up to 70 remote measurements/s via GPIB
•Up to 80 manual measurements/s (screen update)